wiki:OwlOverview

Version 6 (modified by indrek, 8 years ago) (diff)

--

Company logo

OWLTM Overview : Hardware

Introduction

This document describes the hardware components of the OWLTM system. It is written to give an overview of the system on the highest level. It shows the components, connections between the components, connections between the OWLTM and it's platform (ship/buoy/rig) and specifications.

Detailed datasheet? OWLTM Shipborne and OWL MAPTM is attached.
Description of the measurement process is described in introduction to measurement physics?.

Block Diagram

The system has two components:

  • Junction box that holds circuit breakers, power-line communication modem and server. The junction box needs a LAN cable and a regular AC current from mains.
  • Measurement device enclosed in a high durability, climate controlled aluminium box.

The two components are connected via regular two leaded electrical wire.

Specifications

Operational
Sensing 5 to 30 m
Conditions of operation Continuous, Day and Night
Sensitivity for oil products:
Min concentration in water column 1ppm
Min oil thickness on water surface 1μm
Maximum detection depth 3m
Pulse Repetition (Sampling) rate Up to 100Hz
Sensing laser Excimer type, XeCl, 308nm
Hyperspectral detector Ultraviolet(UV) and visible spectral range
GPS Integrated
Control and communication
Operational control Integrated micro-controller
Data storage Local and central servers
Setup of device operation Remote, via local server, embedded WEB
Communication line Power-line communication
Alarm processing Automatic
Data visualization on the map Real-Time
General
Power consumption 150 W/(1500 W arctic)
Input voltage 230VAC/50/60Hz
Dimensions (L x W x H) 65 cm x 45 cm x 37 cm
Weight 40 kg

List of identifiable oil types

  • Light oil
  • Medium oil
  • Crude oil

Safety The LASER in the measurement device is eye safe. See declaration of safety?.

System installation

Company logo

The Measurement device has robust attachment points along the longest edges. If the customer specifies how and where the Measurement Device will be mounted custom made fastenings will be provided. Device drawing with standard fastenings can be found here.

The Junction Box should be installed indoors. The enclosure of the Junction Box is not weatherproof nor climate controlled. It is a metal box that will be mounted on a wall. It requires power and Local Area Network connections. Instruction for

Attachments (7)