wiki:OwlOverview

Company logo

OWLTM Overview

Introduction

This document describes the hardware components of the OWLTM system. It is written to give an overview of the system on the highest level. It shows the components, connections between the components, connections between the OWLTM and it's platform (ship/buoy/rig) and specifications.

Detailed datasheet OWLTM Shipborne and OWL MAPTM is attached.

Description of the measurement process is described in Physics of OWL.

Block Diagram

The system has two components:

  • Junction box that holds circuit breakers, power-line communication modem and server.

The junction box needs a LAN cable and a regular AC current from mains.

  • Measurement device enclosed in a high durability, climate controlled aluminium box.

Also included in the box:

  • 40 meters of heavy duty electrical cable for connecting Junction box and Measurement device. The Measurement device side of the cable has an space grade plug.
  • GPS antenna
  • GPS antenna extension cord. The antenna must not be in the field of strong radio signal(for example ships radar) and the cord provides flexibility of choice on position.
  • Custom made fastenings. The drawing of the railing is necessary for us to manufacture the components.

Specifications

Operational
Sensing 5 to 30 m
Conditions of operation Continuous, Day and Night
Min concentration of oil in water column 1ppm
Min oil thickness on oil on water surface 1μm
Maximum detection depth 3m
Pulse Repetition (Sampling) rate Up to 100Hz
Sensing laser Excimer type, XeCl, 308nm
Hyperspectral detector Ultraviolet(UV) and visible spectral range
GPS Integrated
Control and communication
Operational control Integrated micro-controller
Data storage Local and central servers
Setup of device operation Remote, via local server, embedded WEB
Communication line Power-line communication
Alarm processing Automatic
Data visualization on the map Real-Time
General
Power consumption 150 W/(1500 W arctic)
Input voltage 230VAC/50/60Hz
Dimensions (L x W x H) 65 cm x 45 cm x 37 cm
Weight 40 kg

List of identifiable oil types

  • Light oil
  • Medium oil
  • Crude oil

Safety

The LASER in the measurement device is eye safe. See declaration of safety.

System installation

The Measurement device has robust attachment points along the longest edges. The customers needs to specify where the device is meant to be installed. A drawing of the railing is necessary for us to manufacture the appropriate fastenings.

The Junction Box should be installed indoors. The enclosure of the Junction Box is not weatherproof nor climate controlled. It is a metal box that will be mounted on a wall. It requires power and Local Area Network connections. The image below shows the typical setup.

Example of installed measurement device is shown below.

The system may be accessed from any computer on the same network. If the ship does not have any computer networks the computer in the Junction box will act as a system router and provide network control.

Read also DeploymentPreparation.